Maintenance Object Repair Procedures
9-217
ATM-INTF (TN2305/6)
9
System Technician-Demanded Tests: Descriptions
and Error Codes
and Error Codes
Failure of this test is not logged in the Error Log.
Control Channel Loop-Around Test (#52)
This test is non-destructive. This test queries the circuit pack for its circuit pack
code and vintage and verifies its records.
code and vintage and verifies its records.
Order of Investigation
Short Test
Sequence
Sequence
Long Test
Sequence
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Control Channel Loop Around Test (#52)
X
X
N
Table 9-94.
TEST #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within the allowable time
period.
period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command a few times for a maximum of 5 times.
2. If the problem continues to fail, reset the circuit pack.
3. Retry the command a few times for a maximum of 5 times.
PASS
Communication with this circuit pack is successful.
Any
NO
BOARD
BOARD
This is normal if the test is being done when:
■
the board is not physically in the system.
■
the system is booting up.
Otherwise, there is some inconsistency in the data kept in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page