Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-270
ATM-TRK (Circuit Emulation Service Circuit Pack) 
9
Control Channel Loop Test (#52)
The non-destructive Control Channel Loop Test is part of the maintenance 
subsystem’s 
Common Port Board Testing
 feature. The Common Port Board test 
sends board vintage queries to a port circuit pack and checks the responses. 
CCMS downlink notifications tell the circuit pack which TDM Bus (A or B) carries 
the control channel and which carries the touch tones.
The test passes if the port circuit pack responds. The test aborts if the circuit 
pack does not respond. The test fails otherwise.
Table 9-120.
TEST #50 Connection Audit Test 
Error 
Code
Test 
Result
Description/ Recommendation
None 
2100
ABORT
System resources required for this test are not available.
1. Retry the command up to 5 times at 1-minute intervals.
1019
ABORT
The test aborted because a test was already running on the port.
1. Retry the command up to 5 times at 1-minute intervals.
FAIL
Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS
The circuit pack has been updated with its translation.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check the board translations. 
2. If the ATM-TRK circuit pack is not administered, run add atm trunk 
UUCSS.
3. If the ATM-TRK circuit pack is administered correctly, check the error log. 
4. If ATM-TRK circuit pack is hyperactive, shut down, and reseat the circuit 
pack to force re-initialization.
5. If the ATM-TRK circuit pack is correctly inserted, run busyout board.
6. Run reset board.
7. Run release busy board.
8. Run test board long to re-establish the linkage between the internal ID 
and the port.
Continued on next page