Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-285
AUDIX-BD (AUDIX Circuit Pack)
9
AUDIX-BD (AUDIX Circuit Pack)
The AUDIX-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination. For circuit-pack-level problems, see “XXX-BD
(Common Port Circuit Pack)”.
AUDIX circuit pack combination. For circuit-pack-level problems, see “XXX-BD
(Common Port Circuit Pack)”.
DEFINITY AUDIX consists of a combination of 2 circuit packs that occupy 5 slots
on a port carrier. The tests described in this manual apply only to switch-side
maintenance which tests circuit pack components related to the TDM bus
interface. The AUDIX system has an extensive maintenance strategy that is
described in
on a port carrier. The tests described in this manual apply only to switch-side
maintenance which tests circuit pack components related to the TDM bus
interface. The AUDIX system has an extensive maintenance strategy that is
described in
DEFINITY AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation
(A, B, C, D, or E).
(A, B, C, D, or E).
SS is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
AUDIX-BD
MINOR
test board UUCSS sh
AUDIX Circuit Pack
AUDIX-BD
WARNING
test board UUCSS sh
AUDIX Circuit Pack