Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-309
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)] 
9
Hardware Error Log Entries and Test to Clear 
Values
Table 9-138.
ISDN-BRI Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level 
BRI-PORT
Alarm Level 
ABRI-PORT
ATT-PORT
LGATE-PT
ATTE-PT
On/Off 
Board
Test to Clear 
Value
0
1
0
Any
Any
Any
Any
test port 
PCSSpp sh r 1
1(a)
(a)
Level 1 Status 
Inquiry (#621)
WRN
MAJ/MIN/W
RN
2
OFF
test port 
PCSSpp sh r 2
18
busyout port 
PCSSpp
WRN
OFF
release port 
PCSSpp
130(b)
WRN
ON
test port PCSS 
sh
257(c)
(c)
EPF Inquiry (#622)
WRN
MAJ/MIN/ 
WRN
2
OFF
test port 
PCSSpp sh r 1
513(d)
(d) 
46222
none
(d)
(d)
ON
769(e)
0
none
WRN
MAJ
OFF
1281(f)
NPE Crosstalk 
(#617)
MIN/ 
WRN
2
ON
test port 
PCSSpp l r 2
1537(g)
46210
CRC Error Counter 
(#623)
WRN
MAJ/MIN/ 
WRN
2
OFF
1793(h)
BRI Port Local 
TDM Loop Around 
(#619)
MIN/ 
WRN
2
ON
test port 
PCSSpp l r 2
3841(i)
46208
None
3842(j)
0
None
3843(k)
0
None
3844(l)
46223
None
3845(m)
None
Continued on next page