Maintenance Object Repair Procedures 
9-313
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)] 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test, for example, you may also clear errors generated from other tests 
in the testing sequence.
NOTE:
The NPE Crosstalk Test and the BRI Port Local TDM Loop Around Test are 
not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT.
NPE Crosstalk Test (#617)
This test is destructive.
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain, and provides conferencing functions on 
a per port basis. The NPE Crosstalk Test verifies that this port’s NPE channel 
talks on the selected time slot and never crosses over to time slots reserved for 
other connections. If the NPE is not working correctly, one-way and noisy 
connections may be observed. This test is part of a port’s Long Test Sequence 
and takes approximately 20 to 30 seconds to complete. Crosstalk testing is 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#617)
X
D
BRI Port Local LAN Loop Around Test 
(#618)
X
D
BRI Port Local TDM Loop Around Test 
(#619)
X
D
Electronic Power Feed Restoral Test 
(#620)
X
X
ND
Level 1 Status Inquiry Test (#621)
X
X
ND
Electronic Power Feed Inquiry Test (#622)
X
X
ND
CRC Error Counter Test (#623)
X
ND
Layer 1 Transmission Error Counter Test 
(#624)
X
ND
Receive FIFO Overflow Error Counter Test 
(#625)
X
ND
Clear Error Counters (#270)
X
X
ND