Axis Communications 207W User Manual

Page of 59
 
36 
AXIS 207W/AXIS 207MW - System Options
Maintenance
• Restart - The camera is restarted without changing any of the settings.
• Restore - The unit is restarted and most current settings are reset to factory default val-
ues. The settings that will not be reset are as follows:
• the boot protocol (DHCP or static)
• the static IP address
• the default router
• the  subnet  mask
• the wireless settings
• Default - The default button should be used with caution. Pressing this will return all of 
the camera's settings to the factory default values (including the IP address)
Upgrade Server - See Upgrading the Firmware, on page 40.
Backup - To take a backup of all of the parameters, and any user-defined scripts, click this 
button. If necessary, it will then be possible to return to the previous settings, if settings 
are changed and there is unexpected behavior.
Restore - click the Browse button to locate the saved backup file (see above) and then click 
the Restore button. The settings will be restored to the previous configuration.
Note: 
Backup and Restore can only be used on the same unit running the same firmware. This feature is not 
intended for the configuration of multiple units or for firmware upgrades.
Support
The support overview page provides valuable information on troubleshooting and contact 
information, should you require technical assistance.
Logs & Reports - when contacting Axis support, please be sure to provide a valid Server 
Report with your query.
View Information - The Log file, the Server Report and the Parameter List all provide 
valuable information for troubleshooting and when contacting Axis support.
Configuration
Log Level for Log Files
 - from the drop-down list, select the level of information to be 
added to the Log file
Log Level for Email - from the drop-down list, select the level of information to send as 
email and enter the destination email address.