Solo USA 444 User Manual

Page of 18
Operating Hints 
ENGLISH
  14 
Wide-range nozzle (7): 
 
 
 
 
 
 
 
 
When spraying plants and trees we recommend fixing 
the wide-range nozzle (7) onto the red standard nozzle 
(4). This ensures that a large area can be sprayed at 
one time. Push the wide-range nozzle onto the 
standard nozzle, until the bead engages.
 
In narrow spaces and for aftercare, we recommend 
placing the wide-angle grille (7a) onto the wide-range 
nozzle. This ensures that the spray velocity is reduced 
and the spray is applied more widespread, to prevent 
damage to leaves. 
 
Nozzle attachment (6): 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The nozzle attachment (6) is positioned onto the 
standard nozzle (4) with the selected grille. 
Use the dual grille (6a) when spraying cultures in rows 
(e.g. vines, tomatoes, nurseries), to achieve a good 
covering on the underside of the leaves. 
The deflector grille can be replaced with a dual grille 
(6b). The dual grille provides a 90° - 110° spray 
pattern. The dual grille is usually used for spraying two 
rows at a time. The deflector grille and the dual grille 
can be placed onto the external diameter of the nozzle, 
until the bead engages. 
 
 
 
 
 
 
 
 
Dual nozzle (accessories, part no.: 49 00 137):  
 
 
 
 
 
 
 
 
 
 
 
 
 
Remove standard nozzle (4) from the spray wand and 
push the dual nozzle onto the spray wand. 
7.4  Residual spray medium 
 
Switch off the appliance as soon as no further liquid is 
expelled, when the metering body is correctly 
positioned for spraying, or air bubbles are visible inside 
the lance supply hose.   
The tank will then contain less than 100 ml residual 
medium. 
If you don’t want to refill the tank with spray medium 
and you want to terminate spraying, dilute the residual 
medium with 2 l of water. Dispose of this solution on 
the treated area.  
7.5  Strainer for accessory sets 
 
When using the liquid pump (accessory part no.: 
type 444 Î 44 00 114, type 450 Î 44 00 235) or the 
ULV accessory (part no.: 49 00 479), a strainer is 
integrated into the tank connector. 
The strainer has a mesh size of 0.32 mm. Only use 
original strainer part no.: 25 00 198 with standard mesh 
size when replacing the strainer. 
7.6  Checking the spray medium flow rate 
At the beginning of the spraying season, check whether 
the equipment flow rate (l/min) still corresponds to the 
„Guide values“ table (see also item „Maintenance 
schedule“). 
For this, fill the equipment up to the maximum marker 
with water, start using the equipment and spray for one 
minute exactly at maximum operating pressure. Then 
measure the water volume required to bring the water 
level back up to the maximum marker.  
The actual volume measured represents the flow rate 
of the equipment in l/min at maximum operating 
pressure.  
It should not deviate by more than 10 % from those 
listed in the „Guide values“ table. Should the actual 
value be too low, sediments inside the metering body 
may be the cause. Clean the corresponding parts and 
repeat the checking procedure. 
Fig. 9 
Fig. 10 
Fig. 11