FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: Keep flue open 
when operating unit.
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted with a piezo ignitor. When lightning 
the pilot, follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not 
use any phone in your building.
• Immediately call your gas supplier from 
a  neighborʼs  phone.  Follow  the  gas 
supplierʼs instructions.
• If you cannot reach your gas supplier, call 
the fire department.
C.  Use only your hand to push in or turn gas 
control knob. Never use tools. If the knob 
will not push in or turn by hand, do not try 
to repair it, call a qualified technician. Force 
or attempted repair may result in a fire.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
OPERATING HEATER
Continued 
LIGHTING 
 INSTRUCTIONS
NOTICE: During initial operation 
the  appliance  will  emit  a  slight 
odor for an hour or two. This is 
due to the "burn-in" of the inter-
nal  paints  and  lubricants  used 
in  manufacturing.  For  the  first 
few hours, operate the appliance 
with doors and windows open to 
encourage dissipation of odor.
1.  STOP! Read the safety information, col-
umn 1. 
2.  Make sure equipment shutoff valve is fully 
open.
3.  Set switch in the Local position.
4.  Wait five (5) minutes to clear out any gas. If 
you then smell gas STOP! Follow the safety 
information above. If you don't smell gas, 
go on to the next step.
5.  Turn PilotStat knob to PILOT. Push in on 
PilotStat knob and press Piezo button 
 
until the pilot is lit.
6.  Continue to hold PilotStat knob in until 
LED  blinks  (one  brief  blink  every  two 
seconds)  then  release  knob.  Note:  You 
will need to hold the knob in for about one 
minute.
7.  Turn PilotStat knob to ON See Figure 12, 
page 9.
  WARNING:  Moving  the  Lo-
cal/Remote  switch  can  cause 
the  main  burner  to  come  on 
immediately.  Stand  away  from 
the  main  burner  when  moving 
the local/remote switch to avoid 
possible injury.
USING TRANSMITTER/ 
REMOTE
1.  Move  switch  to  REMOTE  position  (see 
Figure 12, page 9).
2.  Press FAN
 or FLAME
 key within 
30 seconds.
3.  Make sure LED turns on for one second.