Cal Spas LTR20091002 User Manual

Page of 40
2009 Inground Spas
LTR20091002, Rev. B
Pr
eparing f
or 
Your Ne
w Ingr
ound Spa
www.calspas.com
11
Equipment Pack Plumbing Connections
The example shown below is typical for a system with two pumps with external heater and external filter.
Designer Spa Specifications
DIJ401 and DIJ405:
Equipment pack weight = 250 lbs.
DIJ407:
Equipment pack weight = 300 lbs.
One 2.5 HP heat pump
One 4 HP swim pump
Note: Equipment pack cannot exceed 15 feet from 
spa.
Plumbing Connections
IMPORTANT!  Always  check  local  codes  prior  to  any 
inground spa installation. 
Once the spa and equipment are properly located, you 
will want to lay out the plumbing run.
Trenches  should  be  deep  and  wide  enough  to  allow 
all pipes to be buried below the frost line and should 
be in as straight a line from the spa to the equipment 
as possible. Check local code requirements for under-
ground pipes. Always know what is under the ground 
before you dig anywhere.
You will need 2” flex or PVC lines for your suction, in-
take, and air line. In ground spas have marked intake 
and suction lines, making it easy find and connect to 
and from the spa and equipment pack.
The plumbing run should not be any longer than 15 
feet to maximize water pressure. Another way to max-
imize water pressure is to limit (or even eliminate) the 
use of 90˚ elbows in your plumbing run. A more direct 
plumbing run using 45˚ elbows is more efficient, and 
promotes increased water pressure.
Identifying Plumbing Lines
The  spa’s  plumbing  lines  are  clearly  marked  during 
water testing at the factory. This is done to assist in-
stallers in properly identifying the installation. We still 
recommend  that  the  installers  verify  plumbing  lines 
prior to gluing. This can be done by using one of the 
following techniques.