INSTALLATION 
 
 
Electrical Precautions 
CAUTION:  Do NOT apply electrical power to the spa 
unless it is filled with water to the normal water level, 
which is approximately 7" below the spa rim (refer to 
location of water level indicator on face of skimmer).  If 
the spa’s motor/pumps are actuated when there is not 
sufficient water in the unit, the circulation pump could be 
irreparably  damaged.    Not  heeding  this  caution  will 
nullify the warranty.  In addition to damaging the unit, 
operating the unit with insufficient water could cause a 
fire. 
 
Do NOT locate lighting fixtures directly above the 
spa; lighting and electrical receptacles must be located 
at least 5 feet from the spa.  Lighting located between 5 
and 10 feet from the spa must be on a circuit protected 
by a GFCI.  (Refer to National Electrical Code, 680-6.) 
Do NOT use electrically connected devices, such as 
television, radio, telephones, stereo speakers, light or 
cooking devices within 5 feet of the spa when the spa is 
being used. 
 
All fixed metal objects located within 5 feet of the 
spa, such as fence posts, railings, door frames, green- 
house structures, gutters, etc., must be attached to the 
bonding bar on the outside of the spa electrical cabinet 
using #8 solid copper wire.  With #8 solid copper wire, 
bond  the spa to the house electrical panel or ap- 
proved local bond. 
 
An approved ground may be an 8 foot long ground 
rod, a plate electrode, or a buried metal water pipe with 
at least 10 feet of buried pipe.  Check your local building 
code for requirements. Bonding lugs are available at 
your local electrical supply store. (Bond bar location is 
shown below.) 
 
 
 
Outdoor Installation 
If you install the spa outdoors, we recommend that 
you provide a concrete pad for it to rest on.  To do this, 
construct forms for a 4" thick level pad.  Install a #10 
gauge wire mesh 6" x 6" steel reinforced grid.  Attach a 
#8 solid copper wire to the grid with a ground clamp. 
This wire should be long enough to reach the bond bar 
on the spa electrical cabinet (minimum 36"), but should 
NOT be located under the base of the spa.  Then pour 
the concrete pad. 
Drainage 
Whether you install your spa indoors or outdoors, 
you can drain it completely by attaching a garden hose 
to the hose bibb (drain valve) located on the suction 
plumbing of the spa.  Simply run the hose to the house 
sewer line or drain field and open the hose bibb. 
 
Make sure the area surrounding the spa has good 
drainage to keep water from collecting at the base of the 
spa—especially near the equipment area.  If drainage is 
poor, install a drain line and/or gravel drain field.  (Refer 
to illustration below.) 
Indoor Installation 
Water that splashes on the floor during spa use may 
cause a walking hazard and/or structural damage.  Good 
drainage must be provided and proper waterproof build- 
ing materials must be used in the area surrounding and 
beneath the spa.  Take into consideration that high room 
humidity will exist due to high spa water temperatures. 
Providing natural or forced ventilation of the room will 
help maintain comfort and minimize moisture damage 
to the building.  Jacuzzi Whirlpool Bath is not respon- 
sible for damages resulting from excess moisture or 
water spillage.  Consult an architect or engineer for aid 
in designing your indoor installation. 
 
 
 
 
 
SUPPORT, DRAINAGE AND BONDING 
 
BOND BAR 
 
 
 
(SKIRTS 
REMOVED) 
 
 
 
ELECTRICAL 
CABINET 
 
 
 
 
#8 BOND WIRE 
(TO LOCAL BOND) 
 
 
 
 
 
WIRE 
MESH 
GRID 
 
 
 
 
GRAVEL DRAIN FIELD                         4" THICK CONCRETE PAD