OPERATION 
 
Mode Function 
 
Pressing the            button switches spa operation to 
either the ECONOMY or STANDARD  mode.   In the 
economy mode, the spa will heat only during the filter 
cycles and only when the spa water temperature is 20°F 
below the temperature set point.  In the standard mode, 
the spa will continuously heat to the set temperature. 
 
 
 
Automatic Filter Cycles 
 
Your spa will automatically filter itself for 2 hours 
twice each day.  The first filter cycle will begin 1 minute 
after the spa is energized.  The second filter cycle will 
begin twelve hours after the start of the first cycle.  The 
blower will activate for 30 seconds at the start of each 
filter cycle to clean out the air channel.  The low-speed 
jets will constantly run during the filter times (unless the 
high-speed jets are on) and the heater will be enabled. 
 
 
 
Display Messages 
 
These are some of the messages you will see on the 
center display. 
 
Message    Meaning 
 
Economy:  The spa is in ECONOMY mode. 
ECON  is  flashed  alternately  with  the  current 
temperature and COOL until the spa water is 
less than 20°F cooler than the set tempera- 
ture. 
 
Overheat Protection:  Spa is deactivated.  If a  
malfunction    occurs   and    the    spa    water 
reaches  112°F,  the  system  will  completely 
shut down. 
 
Danger:  DO NOT ENTER THE WATER. 
Turn off all power to the spa and contact 
your dealer or service organization.  Press 
any panel button to reset. 
 
Flow Switch  (Constantly displayed):  A pres- 
sure  switch  has  malfunctioned.    Contact 
your dealer or service organization. 
 
Flow Switch (Flashing):  1)  The filter may be 
plugged. Remove the filter and clean.  2) 
The amount of water may be inadequate.  Be 
sure the spa is properly filled.  3)  A pressure 
switch  has  malfunctioned.    The  spa  will 
operate,  but  the  heater  will  not  activate. 
Contact your dealer or service organization. 
 
 
 
 
 
 
 
 
Message    Meaning 
 
Temperature Set Back:  If the spa water is 
more than 20°F cooler than the temperature 
set point, the heater will automatically acti- 
vate.  This is a normal spa function;  no 
corrective action is necessary. 
 
Freeze Protection:  If a freeze condition is 
detected,  the  pump  is  automatically  acti- 
vated.  This is also a normal spa function;  no 
corrective action is necessary. 
 
Open Sensor:  Spa is deactivated.  The high 
limit temperature sensor is nonfunctional. 
This must be repaired by a dealer or service 
organization. 
 
Open  Sensor:  Spa  is deactivated.   The 
water sensor is nonfunctional.  This also 
must  be  repaired  by  a  dealer  or  service 
organization.