GE PT878GC User Manual

Page of 308
3-29
April 2004
Installing the PDJ Dampening Jacket (cont.)
!WARNING!
The pipe and the dripping fluid will cause severe 
burns upon contact with bare skin. Also, be sure 
not to inhale the fumes generated during the 
DMP-3 curing cycle.
4. Install the fixture over the jacket, adjusting the spacing to 
match the prestamped transducer holes and PT878GC spacing 
calculations.
5. Apply a thin bead of CPL-16 couplant. Spread it in a thin layer 
about 6 mm (0.25 in.) wide on each transducer face. 
6. Install the transducers into the yokes, and tighten the hold-
down screws until the couplant begins to spread.
7. If you wish, reinstall insulation over the pipe, making sure that 
the yokes and junction boxes protrude through the pipe.
8. Wait 15 min. for the couplant to cure and finger-tighten the 
transducer hold-down screws. Do not use pliers or any other 
tools.
9. Using a wrench, tighten the transducer hold-down screw 
backing nuts to prevent loosening due to vibration and thermal 
expansion.