Mitsubishi 51P-P626 User Manual

Page of 4
MITSUBISHI MGS SERIES 
DIESEL GENERATOR SET 
50Hz/1500 rpm/11kV 
 
 
 
 
 
 
 
 
POWER RATING (0.8 P.F.) 
MODEL CODE 
STAND-BY  2000 kVA 
51S-P626 
PRIME 
1800 kVA 
51P-P626 
 
 
 
 
 
 
MGS1500HV with typical options 
 
CONDITIONS & DEFINITIONS 
Stand-by: Code: S 
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. 
Fuel stop power in accordance with ISO15550, ISO3046/1, JISB8002-1, DIN6271 and BS5514. 
 
Prime: Code: P 
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. + 10% overload 
in  accordance  with  ISO3046/1.  Overload  power  in  accordance  with  ISO15550,  ISO3046/1,  JIS8002-1,  DIN6271  and 
BS5514. 
 
Conditions:   
Engine ratings are based on SAE J1349 standard conditions and also apply at ISO3046/1, DIN6271 & BS5514 standard 
conditions. 
Fuel rates: based on ASTM D975, BS2869 and on fuel oil of 35° API (16°C or 60° F) gravity having a LHV of 42,780 kJ/kg 
(18,390 Btu/lb.) when used at 29°C (85° F) and weighing 838.9 g/liter (7.001 lbs./U.S. gal.). 
 
 
DIMENSION (Reference Data) 
 
 
 
Overall dimensions 
L :  Length 
mm 
6300 
6300 
 
W :  Width 
mm 
2200 
2200 
 
H :  Height 
mm 
2800 
2800 
Total Weight (Dry) 
 
kg 
15155 
15155 
Total Weight (Wet) 
 
kg 
15755 
15755 
 
 
 
M
M
G
G
S
S
1
1
5
5
0
0
0
0
H
H
V
V
 
 
 
STAND-BY 
2000 kVA 
PRIME 
1800 kVA 
50Hz/11kV