a) Start the generator and adjust the spear valve to obtain 220-240 volts, 0 amps at the 
panel. [Do not turn the circuit breaker on]. 
b) Adjust the potentiometer on the circuit board very slowly to the left. When you 
detect a small decrease in voltage, stop. Turn on the circuit breaker and increase water 
to increase power to the unit. Increase power until a load of 2kW is indicated (P =VI). 
c) If adjusting the potentiometer does not correct the problem, then contact PowerPal. 
The problem is probably with the potentiometer. 
 
 
TECHNICAL SPECIFICATIONS 
 
  
MHG-T2 
 
 
 
1 Rated power output 
2000W
2  Maximum allowable load 
2200W
3 Intended voltage 
220V~
4  Frequency at rated power output 
50 Hz
5  Frequency at runaway speed 
70 Hz
6 Runaway speed 
1500rpm
7 Height 
600mm
8 Weight 
90kg
9  Turbine runner type 
Turgo
10 Runner diameter 
270mm
11 Number of buckets 
20
12 Number of nozzles 
1
13 Generator 
3- phase 
14  Generator insulation 
Class B
15 Protection grade 
IP54
16  Load controller circuit breaker 
20A
17  Upper generator bearing size 
Lower generator bearing size 
Turbine bearing size 
6206-2Z
SKF 7206B
SKF 1207 
18 Seal size 
38x58x10mm
19 Recommended cable 
4mm2
20 Operating temperature 
5 to 50 
° C
21  Operating humidity 
0 to 90%
 
Notes: 
 
1,2. 
Rated power output is the manufacturer’s specified output for the given head 
and flow conditions. A higher output is possible if the head is greater or the flow is 
faster than recommended. If the maximum allowable load is exceeded then permanent 
damage to the stator may occur. 
 
3. 
Is approximately 220V when the ELC is used. 
 
5,6. 
Runaway speed is the speed of the rotor if no load is applied. This speed is 
reduced under load.    
 
18. 
We recommend SKF brand or similar high quality bearings.  
 
Also, the diagrams and much useful information on pages 7 and 16 are taken from 
Micro-hydropower Sourcebook – A Practical Guide to Design and Implementation in 
Developing Countries. 
NRECA, 1986.  
PowerPal™ T2 Turgo 15