dbx Pro QUANTUM User Manual

Page of 94
®
Utilities
Section 5
QUANTUM
49
®
QUANTUM User Manual
1.
Enter the “Utility” menu by pressing the UTILITY button once.
2.
Press NEXT PAGE button until page 8 is reached.
3.
Use the DATA WHEEL to select which setup you would like to dump. 
4.
Press the DATA WHEEL to change the cursor location to the next selection.
5
Select the name of the preset you would like to dump.
6.
Press the UTILITY button to start the dump.
A/D CALIBRATE
This page of “Utilities” is a calibration section for the analog to digital converter chips.  To cal-
ibrate the converters, first turn the input controls of the QUANTUM fully counter-clockwise
(-
). Calibrations performed with these controls open at all could result in inaccurate calibra-
tions, giving the QUANTUM poor processing performance. After the input controls have been
turned to the (-
) position, press the UTILITY button. If the calibration is not successful, the
following text will appear in the third parameter area: “A/D CAL FAIL!” If this happens you
should turn the QUANTUM off then back on. If the problem persists, call dbx technical support
at 1-801-568-7660 for assistance. Call after the unit is allowed to warm up to operating temper-
ature (approx. 10 minutes).
CONTRAST
The contrast selection adjusts the displays visibility.
5.10 Misc.
5.9 A/D  Calibrate
5.8 Setup SYSEX Data (cont.)