PAGE 22 — MQ STOW MS15H/MS15E  MIXER — PARTS & OPERATION MANUAL — REV.FINAL (08/10/06)
This section is intended to assist the operator with
the initial start-up of the  MS-15H (gasoline) or
MS15E (electric) mixer. It is extremely important that
this section be read carefully before attempting to
use the mixer in the field.
DO NOT use your mixer until this section is thoroughly
understood.
Failure to understand the operation of the MS15H/MS15E  mixers
could result in severe damage to the mixer or personal injury.
See Figure 3 for the location of any control referenced in this
manual.
Starting  (gasoline only)
The following steps outline the procedure for starting the engine.
Depending on the type of engine employed in the mixer the
steps may vary slightly. If your mixer has an electric motor
disregard this section.
1.
Move the fuel shut-off lever (Figure 9) to the ON position.
Figure 9. Fuel Shut-OFF Lever
2.
To start a cold engine, move the choke lever (Figure 10) to
the CLOSED position.
Figure 10. Choke Lever
3.
Move the throttle lever (Figure 11) away from the slow
position, about 1/3 of the way toward the fast position.
Figure 11. Throttle Lever
MS15H/MS15E  MIXER  — START-UP PROCEDURES
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION