Topcon GTS-822A User Manual

Page of 144
5-12   
   5 PROGRAM MODES
5
Collimate prism A and press [F1](MEAS) key.
The distance measurement will start.
Horizontal distance is displayed.
Collimate 
[F1]
6
Press [F6] (SET) key, and horizontal distance 
will be recorded.
[F6]
7
Collimate prism B and press [F1](MEAS) key.
The distance measurement will start.
Horizontal distance is displayed.
Collimate 
[F1]
8
Press [F6] (SET) key, and horizontal distance 
will be recorded.
[F6]
9
Sight line point L .
Measured data to the line point L is displayed.
VD:Vertical distance.
HD:Horizontal distance from the instrument to
       L.
Off :Horizontal distance from A to L.
Sight L 
10
Press [F2](LH) key.
This function is used when measuring the line 
height from the ground. The procedure is as 
follows :
l
Sight the point on the line before pressing this 
key.
l
Don‘t move the horizontal tangent screw by 
setting ground point G.
[F2]
LINE
<STEP-1>P
T A
 HD*              < m
MEAS
SET
LINE
<STEP-1>PT A
 HD*          50.234 m
MEAS                   SET
LINE
<STEP-1>PT B
 HD:                m
MEAS                   SET
LINE
<STEP-1>PT B
 HD*              < m
MEAS                    SET
LINE
<STEP-1>PT B
 HD*          67.543 m
MEAS                  SET
LINE
  VD:    20.123 m
  HD:    38.987 m
 Off:    74.123 m
EXIT LH 
LINE
G-POINT
 V :  30°20'10"
EXIT                    SET