Meyer Sound LX-300 User Manual

Page of 48
Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to
an Analog Audio Input module; "DMA1" to a CobraNet module).
CueStation Log Window Messages
CueStation's Log window reports a number of errors from the Matrix3 system. These can be helpful in diagnosing
the root cause of a failure. The messages relevant to booting an LX-300 are:
Explanation
Error Code
No Flash program detected.
M3 E1.5.0, Built on yy/mm/dd, at hh:mm:ss
 
DMEM memory usage exceeded.
Matrix exceeds DSP capacity.
Total Dynamix points exceeded x
ADSIR_InterruptsHaveBackedUp
DSP Usage has reached limit. Halting processing. Please
re-send configuration.
ADSIR_BadSampleDetected
Corrupt audio detected. Muting audio for 1 second.
 
Unmuting audio.
INITMAIN_HSB_Packet_Error
HSB Packet error detected
Flash program memory error
FLASH ReadFile got wrong CRC for file x, wanted y, got
z
 
FLASH ReadRawFile got wrong CRC for file x, wanted
y, got z
Various FPGA programming errors
FPGA still not done after 4mSeconds waiting
 
FPGA Length Mis-Match
 
FPGA program error. Byte x, bit x TotalBits x
 
FPGA 'DONE' not active at end of write.
Various EtherTracks Errors
ETRX: Cannot allocate memory
 
ETRX: Cannot read et_boot.bin (x)
 
ETRX: Corrupted DualPort->HSB transfer. [0x]=0x, should
be 0x
 
Read Again: [0x]=0x, should be 0x
 
ETRX: Could not read et_linux.bin (x, 0x) Trying a second
time
 
ETRX: CRC failed. ET=0x Should be=0x. #P=x LAST[0x]
 
ETRX: # Packets not right. ET=0x Should be=0x. #P=x
LAST[0x]
45