Mitsubishi Electronics QD75MH4 User Manual

Page of 838
 
 
 
8 - 4 
MELSEC-Q
 
8   OPR CONTROL 
 
 OPR sub functions 
 
Refer to Section 3.2.4 "Combination of QD75MH main functions and sub functions" for 
details on "sub functions" that can be combined with OPR control. Also refer to Chapter 
12 "Control sub functions" for details on each sub function.  
 
[Remarks] 
 
The following two sub functions are only related to machine OPR. 
 
Sub function name 
Machine OPR 
Fast OPR 
Reference 
OPR retry function 
 
 
Section 12.2.1 
OP shift function 
 
 
Section 12.2.2 
 
                                                  : Combination possible,  : Restricted,  : Combination not possible 
 
 
 When an OPR is not required 
 
Control can be carried out ignoring the "OPR request flag" (
Md.31
 Status: b3) in 
systems that do not require an OPR.  
In this case, the "OPR parameters (
Pr.43
to 
Pr.57
)" must all be set to their initial 
values or a value at which an error does not occur.  
 
 
 OPR from peripheral devices 
 
"Machine OPR" and "fast OPR" can be executed from the test mode of the peripheral 
device.  
Refer to GX Configurator-QP Operating Manual for details on OPR from the peripheral 
device.