Jacuzzi 2003+ User Manual
Export J-310 / J-320 / J-330 1-Pump Models (50Hz)
230V/20A*
230V/30A**
Voltage:
230 VAC
230 VAC
# of Wires:
3
3
Frequency:
50Hz
50Hz
Current Draw:
15A
21A
Circuit Breaker:
20A
30A
*
In the 20A configuration, the heater will not operate at the same time
as the main jets pump. This is the factory setting.
as the main jets pump. This is the factory setting.
** In the 30A configuration, the heater will operate at the same time as
the main jets pump.
Export J-340 2-Pump Model (50Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A
30A
40A
*
In 20A configuration, the heater will not operate while either jets pump
is running in high speed. This is the factory setting. Note: pump 2
runs only in high speed.
is running in high speed. This is the factory setting. Note: pump 2
runs only in high speed.
** In 30A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater will operate while either jets pump is
running in high speed. Note: pump 2 runs only in high speed.
US / Canada J-340 2-Pump Model (60Hz)
240V/50A*
240V/30A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
36A
24A
43A
Circuit Breaker:
50A, 2-Pole
30A, 2-Pole
60A, 2-Pole
*
In 50A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
are running in high speed. Note: pump 2 runs only in high speed.
This is the factory setting.
** In 30A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** In 60A configuration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.
Page 9