Mitsubishi Electronics A800 User Manual

Page of 116
Inverter component names
9
1
1.2
Inverter component names
Component names are shown below.

Refer to the FR-A800 Instruction Manual (Detailed)
Symbol
Name
Description
Refer to 
page
(a)
RS-485 terminals
Enables RS-485 and Modbus-RTU communication.
(b)
Plug-in option connector 1
Connects a plug-in option or a communication option.
Instruction 
Manual of 
the option
(c)
Plug-in option connector 2
(d)
Plug-in option connector 3
(e)
Voltage/current input switch
Selects between voltage and current for the terminal 2 and 4 inputs.
(f)
Control circuit terminal block
Connects cables for the control circuit.
(g)
PU connector
Connects the operation panel (FR-DU08) or the parameter unit (FR-PU07). 
This connector also enables the RS-485 communication.
(h)
USB A connector
Connects a USB memory device.
(i)
USB mini B connector
Connects a personal computer and enables communication with FR 
Configurator2.
(j)
Front cover
Remove this cover for the installation of the product, installation of a plug-in 
(communication) option, RS-485 terminal wiring, switching of the voltage/
current input switch, etc.
(k)
Power lamp
Stays ON while the power is supplied to the control circuit (R1/L11, S1/L21).
(l)
Alarm lamp
Turns ON when the protective function of the inverter is activated.
(m)
Charge lamp
Stays ON while the power is supplied to the main circuit.
(n)
Operation panel (FR-DU08)
Operates and monitors the inverter.
(o)
Terminal block cover
Remove this cover for wiring.
(p)
Main circuit terminal block
Connects cables for the main circuit.
(q)
Cooling fan
Cools the inverter.
(g)
(f)
(e)
(p)
(k)
(m)
(a)
(d)
(b)
(c)
(n)
(l)
(j)
(o)
(h)
(i)
(q)