Anton/Bauer 70 User Manual

Page of 11
 
 
LED Indications 
The TITAN 70 has three LEDs (one red, two green).  One green LED indicates AC line 
voltage status.  If the green status LED is steady, then line voltage is present.  If the 
green status LED is flashing, then AC Line voltage has been removed. 
 
The red and green LED’s will indicate the charging status of the battery.  The following 
table identifies all of the LED indications and their meaning: 
 
LED INDICATION 
MEANING 
Alternating 
Red & Green 
Indicates that the TITAN 70 is evaluating the battery and/or 
communicating with a DIGITAL battery, loading battery 
parameters and determining the appropriate charge routine.  A 
low voltage (<11V) battery will cause this indication to continue 
until the battery is “rejuvenated” to a safe charging voltage. 
NOTE:  This indication will continue if a non-Anton/Bauer Logic 
Series battery is mounted on the charger.  These batteries cannot 
identify themselves to the TITAN 70 and will not be charged. 
Steady Red 
Indicates that the battery is being held by the TITAN 70 to 
stabilize an out-of-range temperature condition. 
Flashing Red 
Indicates that the battery is currently under Stage One charge. 
Flashing Green 
(slow rate) 
Indicates that the battery is currently under Stage Two charge. 
Flashing Green 
(fast rate) 
Indicates a fully charged DIGITAL battery is placed on the 
charger and a FUL cutoff condition cannot be met.  The charger 
is VERIFYING that the battery is in a full charge condition. 
Steady Green 
Indicates that the battery is READY and in Stage Three Lifesaver 
mode.  
 
Green Status LED 
Red/Green Charge Status LED
APPROVED COPY