Anton/Bauer 2700 User Manual

Page of 16
 
10 
 
When testing is completed, the LCD Main Display will indicate “TEST DONE”.  To 
display or print test results: 
1.  Press the DISPLAY button on the PowerCharger front panel to scroll to the 
Primary Position Display for the battery tested. 
2.  Press the TEST button.  The LCD will display the capacity of the battery in 
ampere hours.  If a printer is attached, performance data will simultaneously be 
printed out with all battery identification information.  Consult your battery 
owners manual for warranty information and cell capacity ratings. 
Remove battery only when test data has been viewed or printed.  Test data is retained 
only while the battery is on the PowerCharger.  Once battery is removed, data is no 
longer available. 
“AUTOCAL” Feature 
When a DDM is installed in the PowerCharger, a special InterActive mode is 
automatically enabled for DIGITAL batteries placed on the PowerCharger at any 
time.  The PowerCharger will interrogate the status of the DIGITAL battery to 
determine whether the battery has received a “learning” cycle or “calibrate” cycle 
within certain parameters.  This “learning” typically occurs in normal equipment 
operation, however, if the battery has not been fully charged and discharged in some 
time, a “double arrow” or “calibrate” indication will appear on the battery.  The 
DIGITAL battery will continue to function normally with this indication.  It is a 
request by the battery to fully charge and discharge the battery to the “EOD” point at 
the next opportune time so that the battery can verify its capacity.  See DIGITAL 
battery Owner’s Manual for complete description of this indication. 
The PowerCharger with DDM will detect a request from the DIGITAL battery and 
automatically enter an AUTOCAL mode when the battery is placed on the charger.  
This mode is indicated by the PowerCharger with an audible alert and a message in 
the LCD advising that the AUTOCAL routine has been called.  This mode can be 
canceled, for example, if time constraints do not allow for the test to be completed.  
The mode is identical to the charge-discharge-charge previously described. 
The AUTOCAL mode can be canceled by following the prompts appearing in the 
LCD, using the TEST button to cancel the test.  If the test is not canceled, it will 
commence automatically. 
When the AUTOCAL operation is complete, the battery will be fully charged and 
ready for use.