Albatron Technology ARM11/Cortex-A8 User Manual

Page of 54
bdi
GDB
 for GNU Debugger, BDI2000 (ARM11/Cortex-A8)
User Manual
 11
© Copyright 1997-2007 by ABATRON AG Switzerland 
V 1.04
2.2  Connecting the BDI2000 to Power Supply
2.2.1 External Power Supply
The BDI2000 needs to be supplied with 5 Volts (max. 1A) via the BDI OPTION connector (Rev.  A)
or via POWER connector (Rev. B/C). The available power supply from Abatron (option) or the en-
closed power cable can be directly connected. In order to ensure reliable operation of the BDI2000,
keep the power supply cable as short as possible. 
For error-free operation, the power supply to the BDI2000 must be between 4.75V and 5.25V DC.
The maximal tolerable supply voltage is 5.25 VDC. Any higher voltage or a wrong polarity
might destroy the electronics.
Please switch on the system in the following sequence:
• 1 --> external power supply
• 2 --> target system
!
BDI 
     TRGT  MODE          BDI MAIN                  
BDI OPTION
13
 
1
14
2
BDI OPTION
  1 - NOT USED
  2 - GROUND
  3 - NOT USED
  4 - GROUND
  5 - NOT USED
  6 - GROUND
  7 - NOT USED
  8 - GROUND
  9 - NOT USED
10 - GROUND
11 - NOT USED
12 - Vcc (+5V)
13 - Vcc Target (+5V)
14 - Vcc (+5V)
Vcc
GND
  Connector
The green LED «BDI» marked light up when 5V power is connected to the BDI2000
Rev. A
BDI 
     TRGT  MODE          TARGET A                     TARGET B
 
POWER
  1 - Vcc (+5V)
  2 - VccTGT
  3 - GROUND
  4 - NOT USED
  Connector
The green LED «BDI» marked light up when 5V power is connected to the BDI2000
RS232
                     POWER      
 LI    TX   RX    10 BASE-T
1 Vcc
2
  GND 3
  4
Rev. B Version
Rev. B/C