Campbell Hausfeld IN632900AV User Manual

Page of 32
3
FP2601
www.chpower.com
General Safety Information 
(Continued) 
 18 . Do not direct paint or other sprayed 
material at the compressor . Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation on 
the compressor .
 19 . When spraying or cleaning with 
solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer .
HOSE PRECAUTIONS
 20 . Inspect hose before use .
Do not exceed working 
pressure marked on hose.
 
Do not twist, bend 
  knot, or abrade 
 
hose.
 21 . Do not wrap hose around body .
 
Keep away from 
  hot surfaces and 
 
chemicals.
Installation
LOCATION
It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F .
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow .
 
Do not locate the  
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
GROUNDING INSTRUCTIONS
1 .   This product is for use on a nominal 
120 volt circuit and has a grounding 
plug that looks like the plug 
illustrated in Figure 1 . Make sure the 
product is connected to an outlet 
having the same configuration 
as the plug . This product must 
be grounded . In the event of an 
electrical short circuit, grounding 
reduces risk of electrical shock by 
providing an escape wire for electric 
current . This product is equipped 
with a cord having a grounding 
wire with an appropriate grounding 
plug . Plug must be plugged into an 
outlet that is properly installed and 
grounded in accordance with all 
local codes and ordinances .
Improper use of grounding 
plug can result in a possible 
risk of electrical shock!
 
Do not use a  
  grounding adapter 
with this product!
2 .   If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal . The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire .
 
Never connect  
  green (or green and 
yellow) wire to a live terminal.
3 .   Check with a qualified electrician or 
serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded . Do not modify 
plug provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician .
 
Overheating, short  
  circuiting and fire 
damage will result from inadequate 
wiring, etc.
TEST
RESET
Grounding pin
Grounded 
outlet
Figure 1 - Grounding method
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air 
compressor pump . When humidity is high or when a compressor is in continuous use 
for an extended period of time, this moisture will collect in the tank . When using a 
paint spray or sandblast gun, this water will be carried from the tank through the 
hose, and out of the gun as droplets mixed with the spray material .
IMPORTANT: This condensation will cause water spots in a paint job, especially 
when spraying other than water based paints . If sandblasting, it will cause the sand 
to cake and clog the gun, rendering it ineffective . A filter in the air line, located as 
near to the gun as possible, will help eliminate this moisture .