Campbell Hausfeld FP260200 User Manual

Page of 24
3
Operating Instructions and Parts Manual 
FP260200
www.chpower.com
Installation (continued)
 
Do not locate the  
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
GrOUnDInG InStrUctIOnS
1.   This product is for use on a nominal 
120 volt circuit and has a grounding 
plug that looks like the plug 
illustrated in Figure 1. Make sure the 
product is connected to an outlet 
having the same configuration 
as the plug. This product must 
be grounded. In the event of an 
electrical short circuit, grounding 
reduces risk of electrical shock by 
providing an escape wire for electric 
current. This product is equipped 
with a cord having a grounding 
wire with an appropriate grounding 
plug. Plug must be plugged into an 
outlet that is properly installed and 
grounded in accordance with all 
local codes and ordinances.
 
Improper 
  use of 
grounding plug can result in 
a possible risk of electrical 
shock!
 
Do not use a  
  grounding adapter 
with this product!
2.   If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire.
 
Never connect green  
  (or green and 
yellow) wire to a live terminal.
3.   Check with a qualified electrician or 
serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded. Do not modify 
plug provided; if it will not fit outlet, 
aSMe Safety valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum.
regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet. Turning the regulator knob 
clockwise (to the right) will increase air 
pressure at the outlet. Turning the knob 
counter-clockwise (to the left) will lower 
air pressure to the outlet. Turning knob 
fully counter-clockwise will shut off flow 
of air completely.
Pressure Gauges - There are two 
gauges located next to the regulator. 
These gauges read air pressure in 
pounds per square inch (psi). The 
gauge on the right shows pressure at 
the outlet. Make sure this gauge reads 
ZERO (by adjusting the regulator) 
BEFORE changing air tools or 
disconnecting hose from outlet. The 
gauge on the left shows pressure in the 
tank indicating compressor is building 
pressure properly. 
Drain valve - This valve is located on 
the bottom of the tank. Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion.
have proper outlet installed by a 
qualified electrician.
 
Overheating, short-  
  circuiting and fire 
damage will result from inadequate 
wiring, etc.
Definition of terms
On / OFF Switch ( I / O ) - Push 
switch to the ON ( I ) position to turn 
compressor on. Push switch to the  
OFF ( O ) position to turn compressor off. 
This switch should be in the OFF ( O 
position when connecting / 
disconnecting power cord from 
electrical outlet or when changing tools.
Pressure Switch (located internally) - 
When the compressor is turned ON, 
this switch will shut compressor off 
automatically when tank pressure 
reaches maximum shut-off / cut-out 
pressure. If compressor remains on and 
air is depleted from tank, this switch 
will allow compressor to automatically 
restart at the restart / cut-in pressure.
handle - Designed to move the 
compressor.
Grounding Pin
Grounded 
Outlet
Figure 1 - Grounding Method
Figure 2 - Power Switch
ON Position
OFF Position
Figure 3 - Drain valve
Figure 4 - Unit Identification
Tank Gauge
Handle
ASME Safety 
Valve
Outlet Gauge
Regulator
Tank
Shroud
ON / OFF Switch
Air Outlet