Campbell Hausfeld MW2500 Series User Manual

Page of 32
MW2500 Series
3
www.chpower.com
Operating Instructions and Parts List
Introduction (continued)
Pressure Switch (located 
internally) - 
When the compressor 
is turned ON, this switch will shut 
compressor off automatically when 
tank pressure reaches maximum shut-
off / cut-out pressure. If compressor 
remains on and air is depleted from 
tank, this switch will allow compressor 
to automatically restart at the restart / 
cut-in pressure.
regulator - The regulator controls 
the amount of air pressure released at 
the hose outlet. Turning the regulator 
knob clockwise (to the right) will 
increase air pressure at the outlet. 
Turning the knob counter-clockwise 
(to the left) will lower air pressure to 
the outlet. Turning knob fully counter-
clockwise will shut off flow of air 
completely.
Pressure Gauges - There are two 
gauges on this compressor. These 
gauges read air pressure in pounds 
per square inch (psi). The larger 
gauge shows pressure at the outlet. 
Make sure this gauge reads ZERO 
(by adjusting the regulator) BEFORE 
changing air tools or disconnecting 
hose from outlet. The small gauge 
shows pressure in the tank indicating 
compressor is building pressure 
properly. 
Installation
LOcatIOn
It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
104°F.
A minimum clearance of 18 inches 
between the compressor and a wall 
is required because objects could 
obstruct air flow.
 
Do not locate the  
 compressor 
air inlet near steam, paint spray, 
sandblast areas or any other source 
of contamination. This debris will 
damage the motor.
GrOUnDInG InStrUctIOnS
1.  This product is for use on a 
nominal 120 volt circuit and has a 
grounding plug that looks like the 
plug illustrated in Figure 3. Make 
sure the product is connected 
to an outlet having the same 
configuration as the plug. This 
product must be grounded. In 
the event of an electrical short 
circuit, grounding reduces risk of 
electrical shock by providing an 
escape wire for electric current. 
This product is equipped with a 
cord having a grounding wire 
with an appropriate grounding 
plug. Plug must be plugged into 
an outlet that is properly installed 
and grounded in accordance with 
all local codes and ordinances.
aSMe Safety valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum.
handle - Designed to move the 
compressor.
Drain valve - This valve is located on 
the bottom of the tank. Use this valve 
to drain moisture from the tank daily 
to reduce the risk of corrosion.
Motor reset - (not shown, located 
inside motor). Designed to keep the 
motor from overheating. The motor 
has an auto reset protector. To reset 
once the motor has cooled, turn the 
switch to the OFF position, then to the 
ON position.
 
This compressor is  
 equipped with an 
overload protector which will shut off 
motor if it becomes overloaded.
 
If the overload  
 protector is 
actuated, the motor must be allowed 
to cool down for approximately 30 
minutes before it will reset.
Figure 1
Regulator
Tank Gauge
Outlet Gauge
Handle
ASME Safety Valve
ON / OFF Switch
Shroud
Tank