SPRAYING PRECAUTIONS
 
Do not spray 
  flammable materials 
in vicinity of open flame or near ignition 
sources including the compressor unit.
24. Spray in a well ventilated area, to keep 
fumes from collecting and causing 
health and fire hazards.
25. Do not spray in vicinity of open flames 
or other places where a spark can 
cause ignition. Do not smoke when 
spraying paint, insecticides, or other 
flammable substances.
26. Use a respirator when spraying.
27. Do not direct paint or other sprayed 
material at the compressor. Locate 
compressor as far away from 
the spraying area as possible to 
minimize overspray accumulation 
on the compressor.
28. When spraying or cleaning with 
solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.
29. Do not smoke when spraying paint, 
insecticides, or other flammable 
substances.
30. Use a face mask/ 
respirator when spraying 
and spray in a well 
ventilated area to 
prevent health and fire 
hazards.
31. Household use only.
32. To reduce the risk of electrical shock, 
do not expose to rain. Store indoors.
Assembly
FOOT ASSEMbLY (FIGURE 1)
Foot assembly kit includes:
-  3 rubber feet
-  3 bolts
-  6 washers
-  3 nuts
Installation
LOCATION
It is extremely important to install the 
compressor in a clean, well ventilated area 
where the surrounding air temperature 
will not be more than 100°F.
A minimum clearance of 18 inches between 
the compressor and a wall is required 
because objects could obstruct air flow.
 
Do not locate the 
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. This 
debris will damage the motor.
Household use only. Store indoors.
ELECTRICAL INSTALLATION
1.  Check and tighten all bolts, fittings, 
etc., before operating compressor.
2.  Operate compressor in a ventilated 
area so that compressor may be 
properly cooled.
3.  Compressor should be located where 
it can be directly plugged into an 
outlet, but if this is not possible, an 
extension cord may be used. It should 
be selected using the extension cord 
chart on page 3 as a guide.
4.  To avoid loss of power and 
overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.
WIRING
1.  Local electrical wiring codes 
differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum .
2.  Use a slow blow fuse type T or a 
circuit breaker.
 
 overheating, short  
   circuiting and fire 
damage will result from inadequate 
wiring, etc.
 
All wiring and  
  electrical 
connections should be performed by a 
qualified electrician. installation must 
be in accordance with local codes and 
national electrical codes.
NOTE: 120 volt, compressor can be 
operated on a 120 volt, 15 amp circuit 
under the following conditions:
a. No other electrical appliances or 
lights are connected to the same 
branch circuit.
b. Voltage supply is normal.
c. Extension cords are of the 
minimum gauge specified in this 
instruction manual.
d. Circuit is equipped with a 15 amp 
circuit breaker or a 15 amp slow 
blow fuse type T.
3.  If above conditions cannot be met 
or if nuisance tripping of current 
protection device occurs, it may be 
necessary to operate compressor 
from a 120 volt, 20 amp circuit.
GROUNDING INSTRUCTIONS
This product must be grounded. In 
the event of an electrical short circuit, 
grounding reduces the risk of electric 
shock by providing an escape wire 
for the electric current. This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug. The plug must be 
plugged into an outlet that is properly 
installed and grounded in accordance 
with all local codes and ordinances.
 
improper installation 
  of the grounding plug 
is able to result in a risk of electric shock.  
when repair or replacement of the cord or 
plug is required, do not connect the 
grounding wire to either flat blade 
terminal.  The wire with insulation having 
an outer surface that is green with or 
without yellow stripes is the grounding 
wire.
 
 Do not use adapter 
   with this product!
  Power cord 
White 
Line 
No
  Motor cord 
White 
Load 
No
  Power cord 
Black 
Line 
Yes
  Motor cord 
Black 
Load 
Yes
✽ 
Wire and Terminal Guide
  Wire 
Color 
Terminal 
Hot
(✽) When the unit is not in operation
TEST
RESET
Figure 2 - Grounding Method
Grounding 
Pin
Grounded 
Outlet
www.chpower.com
Rubber Foot
Washer
Bolt
Washer
Nut
Figure 1 - Rubber foot installation