Campbell Hausfeld HX5100 User Manual

Page of 24
3
HX5100, HX5101
www.chpower.com
assembly (Continued) 
IntaKE fIltEr
Thread the intake air filter into the 
threaded opening in the side of the 
compressor head as illustrated in Figure 
4. Tighten gently with a wrench.
figure 4 - Intake filter installation
Installation
loCatIon
It is extremely important to install the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.
 
Do not locate the  
 compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
ElECtrICal InStallatIon
 
All wiring and  
 electrical 
connections should be performed by a 
qualified electrician. Installation must 
be in accordance with local codes and 
national electrical codes.
WIrInG
1.   Local electrical wiring codes differ 
from area to area. Source wiring, 
plug and protector must be rated for 
at least the amperage and voltage 
indicated on motor nameplate, and 
meet all electrical codes for this 
minimum.
2.   Use a slow blow fuse or a circuit 
breaker.
3.   Make sure the product is connected 
to an outlet having the same 
configuration as the plug. This 
product must be grounded. In the 
event of an electrical short circuit, 
grounding reduces risk of electrical 
shock by providing an escape wire 
for electric current. This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug. Plug must be 
plugged into an outlet that is 
properly installed and grounded in 
accordance with all local codes and 
ordinances.
 
Overheating, short 
 circuiting and fire 
damage will result from inadequate 
wiring. 
2.   Place lock washer on axle bolt. Then 
tighten nut securely to threaded 
part of axle bolt.
3.   Repeat procedure with other side.
lUBrICatIon
 
THIS UNIT IS  
 SHIPPED WITHOUT 
OIL IN PUMP! Follow lubrication 
instructions before operating 
compressor.
Use oil shipped with the compressor. Do 
not use regular automotive oil such 
as 10W-30.
 Additives in regular motor 
oil can cause valve deposits and reduce 
pump life. For maximum pump life, 
drain and replace oil after the first few 
hours of run time. 
The compressor pump takes 
approximately 280 ml (9.5 ozs.) of oil. 
The sight glass, located on the crankcase 
portion of the pump, is marked 
with “max” and “min” levels. Avoid 
overfilling by adding oil gradually and 
checking the oil level with the sight 
glass several times. Add enough oil to 
reach the “max” level on the sight glass. 
Proper oil level is illustrated in Figure 3.
figure 3 - proper oil level
Max.
Min.
figure 6 - Unit Identification
Intake filter
Oil fill / breather
Sight 
glass
Handle
Oil drain plug
Drain valve
Check 
Valve
Safety 
Valve
Regulator
Exhaust 
Tube
Pressure Switch 
(Auto/Off)
Side view of unit
Top view of unit
Extension cords
length of Cord (ft)
25
50
100
Gauge of Cord
14
12
10