Campbell Hausfeld FP202801 User Manual

Page of 24
FP202801, FP202901
3
www.chpower.com
Operating Instructions and Parts List
 Introduction
 R efer to Figure 3 to locate the 
following items.
ON / OFF Switch ( I / O ) - Push 
switch to the ON ( I ) position to turn 
compressor on. Push switch to the OFF 
O ) position to turn compressor off. 
This switch should be in the OFF ( O ) 
position when connecting / 
disconnecting power cord from 
electrical outlet or when changing 
tools.
Pressure Switch (located 
internally)- 
When the compressor 
is turned ON, this switch will shut 
compressor off automatically when 
tank pressure reaches maximum shut-
off / cut-out pressure. If compressor 
remains on and air is depleted from 
tank, this switch will allow compressor 
to automatically restart at the restart / 
cut-in pressure.
Drain Valve - This valve is located on 
the bottom of the tank. Use this valve 
to drain moisture from the tank daily 
to reduce the risk of corrosion.
Motor Reset - (not shown, located 
inside motor). Designed to keep the 
motor from overheating. The motor 
has a self-hold protector. If the unit 
is over worked, a thermal limiter will 
shut unit off. If it happens, switch the 
unit to the OFF position and unplug 
the unit. Wait 30 minutes, plug the 
unit in and switch the unit to the 
ON position again to resume work.
 
This compressor is 
 equipped with an 
overload protector which will shut off 
motor if it becomes overloaded.
 
If the overload 
 protector is 
actuated, the motor must be allowed 
to cool down for approximately 30 
minutes before it will reset.
Regulator - The regulator controls 
the amount of air pressure released at 
the hose outlet. Turning the regulator 
knob clockwise (to the right) will 
increase air pressure at the outlet. 
Turning the knob counter-clockwise 
(to the left) will lower air pressure to 
the outlet. Turning knob fully counter-
clockwise will shut off flow of air 
completely.
Pressure Gauges - There are two 
gauges located next to the regulator. 
These gauges read air pressure in 
pounds per square inch (psi) The larger 
gauge shows pressure at the outlet. 
Make sure this gauge reads ZERO 
(by adjusting the regulator) BEFORE 
changing air tools or disconnecting 
hose from outlet. The small gauge 
shows pressure in the tank indicating 
compressor is building pressure 
properly. 
ASME Safety Valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum.
Handle - Designed to move the 
compressor.
Figure 1
Figure 2
Figure 3
Regulator
Tank Gauge
Regulator Gauge
Handle
ASME Safety Valve
Tank Drain Valve
ON / OFF Switch
Shroud
Tank