Datalogic Scanning DX30 User Manual

Page of 197
GRYPHON™ Dx30/Mx30 
5.2.5 Inter-Block 
Delay 
 
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 
characters each. The inter-block delay parameter allows setting a delay between 
each block sent to the Host. 
 
 
 
5.3 DATA 
FORMAT 
 
The system always provides gun to host data communication using the following 
message formatting: 
 
Output Message from Gryphon™ Dx30 or Gryphon™ Mx30 Stand Alone Towards 
Host 
[Header] [Gun_Addr] [Gun_Addr_delimiter] ] [Code ID] [Code Length] 
CODE
 
[Terminator]
 
 
[Items in square brackets are optional.] 
 
 
Output Message from Gryphon™ Mx30 STAR-System™ Towards Host 
[Header] [Code ID] [Code Length] 
CODE
 [Terminator]
 
[Items in square brackets are optional.] 
 
 
 
5.3.1 Header/Terminator 
Selection 
 
The header/terminator selection is not effected by the reading of the restore default 
code. In fact, header and terminator default values depend on the interface selection: 
RS232:  
no header, terminator CR-LF 
WEDGE:  
no header, terminator ENTER 
These default values are always restored through the reading of RS232 or WEDGE 
interface selection code, see chapter 2. 