5.10 BATTERY SELECTION 
 
Battery selection is required only when the Gryphon™ Mx30 reader has an Alkaline 
battery and you want to use OM-Gryphon™ or C-Gryphon™ either for serial 
configuration, software upgrades or to hold Gryphon™ Mx30. Since this type of 
battery must not be charged it is necessary to disable the OM-Gryphon™ or 
C-Gryphon™ charge function by following the procedure: 
 
With the Gryphon™ Mx30 read the following code: 
 
1. 
 
Alkaline 
Ì$+RN4$-]Π
 
 
The green LED on the Gryphon™ Mx30 will blink, signaling the reader has 
accepted the command. 
 
 
2. 
Place the reader onto the charger within 10 seconds. The green LED turns 
off and a short beep is emitted 
 
 
To enable the charge function repeat step 1 and 2 substituting the "Alkaline" code 
with the following one: 
 
NiMh 
Ì$+RN6$-gΠ
 
 
 
 
CAUTION 
Attempts to charge Alkaline batteries could cause leakage of liquid, 
generation of heat or, in extreme cases, explosion. If using Alkaline 
batteries, carefully follow the procedure above to avoid damage. 
 
 
157