Datalogic Scanning 1000 User Manual

Page of 62
INSTALLATION 
11
 
2.3 ELECTRICAL 
CONNECTIONS 
 
The Matrix-1000
 reader is equipped with a 25-pin male D-Sub connector for 
connection to the power supply and input/output signals. The details of the connector 
pins are indicated in the following table: 
 
 
13
25
14
 
Figure 10 - 25-pin male D-Sub Connector 
 
25-pin male D-sub connector pinout 
Pin Name 
Function 
SHIELD 
Cable shield internally connected by capacitor to the 
chassis 
RTX485+ 
Rx or Tx data of RS485 Half Duplex Main Interface - 
positive pin 
RTX485- 
Rx or Tx data of RS485 Half Duplex Main Interface - 
negative pin 
SGND 
Reference GND of RS485 Half Duplex Main Interface 
3,5 NC 
 
20 
RXAUX 
Received data of RS232 Auxiliary Interface 
(referred to GND) 
21 
TXAUX 
Transmitted data of RS232 Auxiliary Interface 
(referred to GND) 
8, 22 
NC 
Not connected 
11, 12 
NC 
Not connected 
16 
OUT 3 + 
Configurable digital output 3 - positive pin 
17 
OUT 3 - 
Configurable digital output 3 - negative pin 
18 
EXT_TRIG A 
External trigger (polarity insensitive) 
19 
EXT_TRIG B 
External trigger (polarity insensitive) 
6, 10 
NC 
Not connected 
14, 15, 24  NC 
Not connected 
9,13 
VS 
Supply voltage - positive pin 
23, 25 
GND 
Supply voltage - negative pin