INSTALLATION 
17
 
2.3.3 
Auxiliary RS232 Interface 
 
The RS232 auxiliary interface is available for Point-to-Point connections. When it is 
connected to the host computer it allows both transmission of code data and reader 
configuration by VisiSet™. 
 
Its communication parameters (baud rate, data bits, etc.) can be defined by the 
user. For more details refer to the "Communication" folder in the VisiSet™ Help 
On Line. 
 
The RS232 interface is available on both Matrix-1000™ D-sub connectors with the 
following pinouts: 
 
9-Pin 25-Pin 
Name 
Function 
2 21 
TXAUX 
Transmitted 
data 
3 20 
RXAUX 
Received 
data 
5 23 
GND 
Ground 
 
 
 
MATRIX
21
TXAUX
RXAUX
20
USER INTERFACE
 
RXD 
TXD 
23
GND
Ground
 
Earth 
Ground
 
1
 
SHIELD
 
Figure 15 - RS232 Interface Connections Using 25-pin Connector 
 
 
 
MATRIX
2
 
TXAUX
RXAUX
3
 
USER INTERFACE
 
RXD 
TXD 
5
 
GND
Ground
 
 