Datalogic Scanning MX30 User Manual

Page of 197
HOST CONFIGURATION STRINGS 
HOST CONFIGURATION STRINGS 
 
 
In this section we provide a description of how to modify the device configuration 
using serial strings sent from the Host. 
This method requires either the RS232 or USB-COM interface. 
 
The device configuration can be changed by receiving commands from the Host 
through the serial interface. When this method is used, the programming sequence 
format is the following: 
 
Command
Character sequence in following tables
CR
$-
$+
Carriage return character (0D Hex.)
Enter configuration environment
Exit and Save configuration
 
 
Example: 
Beeper tone 1
Beeper low intensity
BG1
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132
BH0
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
$+
Enter configuration environment
Multiple command programming sequence:
 
 
Each configuration parameter setting removes the condition previously active for that 
parameter. 
 
 
 
NOTE 
The device buffer can contain about 400 characters. If your 
programming string goes over this value, you must split it into separate 
groups and send each group after a delay of at least 3 seconds to give 
the reader time to empty the buffer and interpret the commands. 
 
 
167