Technical Specifications 
Environmental Parameters
Parameter 
Specification 
Mechanical Shock 
Multi 1.0m drops 
Contaminants 
Water and Dust 
IP52 
Temperature Ranges: 
Operating 
Storage 
32
 F to +122 F (0 C to +50 C) 
-104
 F to +158 F (-40 C to + 70C) 
Ambient Light Indoor 
0 - 6000 lux 
Ambient Light Outdoor 
0 - 86,100 lux 
Humidity 
5 to 95% non-condensing 
Beeper/Speaker 
70-85dBA at a distance of 3’-3” (1 meter) 
Vibration 
Retail/Office 
Sine: 3.0 g pk, 5 Hz to 500 Hz 
Random: 0.030 g
2
/Hz, 5 Hz to 1000 Hz 
Magellan
®
 1100i OEM 