Avaya 8400B Plus User Manual

Page of 198
Isolating Problems Using Loopback Data Tests
D-4
Issue 2   November 1996
Performing a Local Loopback Test
To initiate the test, type:
AT&T1 
Type any string of characters. Compare the characters on the screen with those 
you typed. If the data does not match, troubleshoot your EIA Connector cord 
and terminal. If these are operating correctly, your data module may be 
defective. Call the Lucent Technologies Technical Service Center at 
1 800 242-2121.
This test will continue for the period of time indicated in S-register 
S18
. To 
terminate the test before the test timer expires, type:
+++
The system responds with:
OK
Type:
AT&T0 
The system responds with:
OK
Local Loopback Test with Self-Test
This test evaluates the data module’s transmit and receive circuitry by having 
the data module generate test characters internally. At the end of the test, the 
8400B Plus Data Module displays a three-digit number indicating the number of 
errors that occurred during the test. If you receive an error count other than 
zero, you may have a defective data module. Call the Lucent Technologies 
Technical Service Center at 1 800 242-2121.
ENTER
ENTER