Disable Busyout Feature During Local 
Loopback Test
This option is set, by default, for Yes. The 8400B Plus Data Module will not 
busyout the DCP line while performing a Local Loopback Test or Local 
Loopback Self-Test.
Changing this option to No allows the 8400B Plus Data Module to busyout the 
DCP line when either the Local Loopback or Local Loopback Self-Test mode is 
entered. This will cause a busy signal when the set is called. The busyout 
condition is released when the test ends. 
NOTE:
A change in the setting of this option becomes effective immediately when 
the 8400B Plus Data Module is in the idle mode or as soon as it is 
returned to the idle mode. The 8400B Plus Data Module is in idle mode 
any time that it is not in a test mode or connected to an active data call.
Changing Installation Options 
All seven installation options are set in S-register 
S24
 via a number that 
represents their collective value.
To accept the default value of Yes for all options, leave the value of 0 
(zero) in S-register 
S24
.
To specify No for only one of the options, enter its value (see Table 2-1) 
in S-register 
S24
. For example, to change Automatic Speakerphone 
Activation to No, enter 64 in S-register 
S24
.
To specify No for two or more options, add together the value for each of 
those options (see Table 2-1), and enter the total in S-register 
S24
. For 
example, to set With Telephone to No and Disable Data Metering 
Feature 
to No, enter 17 in S-register 
S24
.