Configuration Parameters
Issue 2   November 1996
3-7
EXAMPLE 3: Changing data options.
AT E1 &D2 S0=5 
This command line is a command sequence that sets up the 8400B Plus Data 
Module to set the command echo option, the DTR option, and the automatic 
answer option. The commands set the following parameters:
AT
 is the required command prefix.
E1
 causes characters entered from the keyboard to be echoed to the 
screen while in command mode.
&D2
 causes the 8400B Plus Data Module to hang up the call when the 
local terminal turns off DTR.
S0=5
 causes the 8400B Plus Data Module to enter automatic answer 
mode and answer incoming calls on the fifth ring.
Configuration Parameters 
Values for configuration parameters are selected by using 
AT
 commands. For a 
description of all 
AT
 commands used by the 8400B Plus Data Module, refer to 
Appendix A.
Parameter Storage and Retrieval 
Configuration parameter values include the option values selected by 
AT
 
commands that require option values and the values stored in the S-registers. A 
set of configuration parameter values is called a profile. The 8400B Plus Data 
Module has four configuration profiles at any given time: one active, two stored, 
and one that permanently contains the factory-default values.
Unsaved changes to configuration parameters remain in effect until they are 
changed again, or until the 8400B Plus Data Module is disconnected from the 
AC power source. Before making or storing any changes, or checking changes 
that you have made, you can issue an 
AT
 command to view the values that are 
currently in the active profile and the two stored profiles.
ENTER