Avaya 8400B Plus User Manual

Page of 198
Configuration and Operation
3-10
Issue 2   November 1996
Data Operation 
This section provides information on how to use the 8400B Plus Data Module 
for data calls.
From Data Mode to Command Mode and Back 
An escape sequence
+++
 , can be typed at any time during a data call to return 
temporarily to command mode. Your call does not disconnect, but data is not 
exchanged. Once you have “escaped” to command mode, the 8400B Plus Data 
Module returns 
OK
 to acknowledge that it has entered command mode (see 
).
At this point, you can issue commands to the 8400B Plus Data Module. As long 
as the data call has not been disconnected, you can use the 
ATO
 command to 
return to data mode.
One other condition will cause the 8400B Plus Data Module to switch from data 
mode to command mode. If the PBX senses that the remote device has 
disconnected, it will disconnect the call to the 8400B Plus Data Module. The 
8400B Plus Data Module will turn off the green LED, turn on the red LED if it is 
not already on, display a result code message on your terminal screen (such as 
NO CARRIER), and then return to command mode.
The escape sequence and all other commands discussed in this section are 
explained in Appendix A.
Dialing a Data Call 
The dial command is issued to the 8400B Plus Data Module in the form 
ATDTnnn...n
, where 
D
 is the dial command, 
T
 is the dial modifier (see 
Appendix B for more information on dial modifiers), and 
nnn...n
 represents 
the number you wish to dial. The command line can hold up to 40 characters, so 
you can usually precede the 
D
 with other commands on the same line.