Troubleshooting
Issue 2   November 1996
4-9
Result codes are not 
displayed when 
commands are 
entered.
The display result 
codes option is 
turned off.
Turn on the display result codes option 
by typing
ATQ0 
Numeric code 
returned when 
verbose message is 
preferred.
The result code 
format option is set 
to numeric form.
Change the result code format option 
to verbose form by typing
ATV1 
Commands are 
displayed without 
error as they are 
typed (echoed), but 
the 8400B Plus Data 
Module does not 
respond to any 
command.
The local terminal 
device is set to a 
speed not 
supported by the 
8400B Plus Data 
Module.
Set the terminal device for one of the 
supported speeds: 300, 1200, 2400, 
4800, 9600, or 19200 bps.
The CONNECT 
message is sent 
without a speed 
indication, but the 
far-end device is not 
set at 300 bps.
The 8400B Plus 
Data Module is 
configured to 
display only the 
basic set of result 
codes (option 
X0
).
Configure the 8400B Plus Data Module 
to send CONNECT 
nnnn
 messages 
for all speeds except 300 bps by typing
ATX4 
Table 4-1.
Troubleshooting Guidelines — Continued  
Symptom
Problem
Solution