20 mA Current Loop (C-Box 100 w/INT-30 Accessory Only) 
 
To adapt DS4600A to 20 mA current loop interfaces, it must be connected to a  
C-BOX 100 equipped with an INT-30 (20 mA current loop adapter accessory board). 
 
The INT-30 converts RS232 communication on the scanner into 20 mA current loop 
signals to the host. See the C-BOX 100 Installation Manual and the INT-30 
instructions.
 
 
 
2.3.3 
Auxiliary RS232 Interface 
 
The auxiliary serial interface is used exclusively for RS232 point-to-point 
connections. 
 
The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well as 
particular communication modes such as Local Echo can be defined using the 
WinHost utility program or Host Mode programming. For more details refer to 
paragraph 2.6 and to the section "Auxiliary Interface Menu" in the WinHost Help On 
Line. 
 
The following pins of the 25-pin connector are used to connect the RS232 auxiliary 
interface: 
 
Pin Name 
Function 
20 
RXAUX 
auxiliary RS232 received data 
21 
TXAUX 
auxiliary RS232 transmitted data 
23 
SGND Aux 
signal ground auxiliary interface 
 
 
 
SGND
DS4600A 
USER INTERFACE
TXD
RXAUX
20
RXD
TXAUX
21
SGND Aux
23
 
Figure 13 - RS232 Auxiliary Interface Connections 
 
When the auxiliary interface is permanently connected as part of the system cabling, 
it is recommended to connect the cable shield to earth ground. 
 
 