Datalogic Scanning DS4600A User Manual

Page of 63
DS4600A 
The electrical features of the inputs are: 
 
Maximum voltage = 30 Vdc 
Maximum current = 25 mA. 
 
An anti-disturbance hardware filter is implemented on the External Trigger input (< 5 
milliseconds delay). 
 
An additional 15 ms (typical) delay can be implemented through a dedicated software 
parameter (refer to WinHost Help On Line). 
 
 
2.3.5 Outputs 
 
The following pins are present on the 25-pin connector of the scanner: 
 
Pin Name 
Function 
OUT1+ 
output 1 + 
22 
OUT1- 
output 1 - 
11 
OUT2+ 
output 2 + 
12 
OUT2- 
output 2 - 
 
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No 
Read, Right or Wrong). Refer to WinHost Help On Line. 
 
By default, OUT1 is associated with the No Read event, which activates when the 
code signaled by the External Trigger is not decoded. OUT2 is associated with the 
Right event, which activates when the code is decoded correctly. 
 
 
DS4600A 
USER INTERFACE 
22/12
8/11
+
40 Vdc max 
Vext
-
 
 
Figure 18 - Open Collector Output Connection 
 
These outputs are both level or pulse configurable. 
16