Baracoda Barcode Reader User Manual

Page of 25
 
Baracoda DualRunners – User Guide v1.7 
 
- 18 - 
Data Capture 
for Workforce 
in Motion 
7.3 How to Read / Write TAG Memory 
 
All  RFID  tags  have  an  unique  identifier  (Tag  ID),  and  some  of  them  have  also  a  non-volatile  memory  (TAG 
Memory) in which it is possible to read and write (with or without security).  
Note: the TAG ID of a RFID tag is different from its TAG MEMORY.  
Unlike reading a tag ID, the read / write memory (TAG MEMORY) operation is only possible in real time. As a 
consequence, the Host has to be connected the DualRunners. This is the host that sends commands to read / 
write in the memory. 
During  this  read/  write  operation,  the  RSL  led  will  be  orange  (solid).  When  there  is  a  lack  of  data  exchanges 
between the tag and the DualRunners (ie : interrogator), it will emit a “Tic” sound. In that case, approach it to 
the tag in order to complete successfully the ‘read / write’ operation. 
 
 
7.4 The different usage modes 
 
Real Time mode
 
In real time mode, the data is decoded and transmitted to the remote host without any delay. If the scanner is 
not connected, the data is lost (Status RSL Led: red flash). 
 
Real Time mode with No Data Loss option
 
If  the  No  Data  Loss  option  is  activated  and  if  the  scanner  is  not  connected  or  out  of  Bluetooth  range,  the 
scanner  will  store  the  data.  It  can  memorise  up  to  20  000  barcodes  (UPC  format)  or  TagID  and  later 
automatically upload them to the remote host when a Bluetooth connection is established to the host.  
Every data sent to the host must be acknowledged by the host. If the host fails to send an acknowledgement, 
the scanner will continue to transmit the data until the host does send an acknowledgement. 
This  acknowledgment  is  disabled  in  the  default  settings.  It  is  strongly  recommended  to  set  the  No  Data  Loss 
mode  to  ON.  This  configuration  can  be  set  with  the  BaracodaManager  software  or  with  the  Programming 
Guide. 
Additionally, this protocol acknowledgment allows an end user to set an audio acknowledgment indicating that 
the data has been successfully transmitted to the host.  
 
Batch mode
 
Datas are always stored in the scanner. Once the batch mode is selected, the BCL led (right) emits an orange 
flash. In batch mode, the DualRunners can read up to 20 000 barcodes (UPC format) or TagID and store them 
into its non-volatile memory for later transmission to the host. 
To  upload  datas  from  the  scanner,  connect  it  to  the  host  computer  via  Bluetooth.  The  BaracodaManager 
software  is  used  to  configure  the  location  where  the  datas  are  sent  once  the  datas  are  extracted  from  the 
scanner.