Mentor v8.6_4 User Manual

Page of 831
Timing Command Dictionary
SET FIRST_FORCE TIME
FastScan and FlexTest Reference Manual, V8.6_4
A-41
SET FIRST_FORCE TIME
Scope: Sets timing information
Usage
SET FIRST_FORCE TIME integer
Description
Sets input pin force time for the first timeframe.
By default, pin forces for all unspecified pins occur at time 0 in the first
timeframe. This command lets you specify a later time for the first input pin force.
Note that this timing file command is similar to the INIT_FORCE_PI statement
that FastScan uses in its
 description.
Arguments
integer
The first force time for all input pins in the first timeframe.
 Examples
The following timing file command changes the default first force time from 0ns
to 5ns.
SET FIRST_FORCE TIME 5;
Related Commands