Fujitsu PRIMERGY RX300 S6 VFY:R3006SF020GB Leaflet

Product codes
VFY:R3006SF020GB
Page of 2
Minimum
Typical
Maximum
Idle Category  (1S and 2S only)
ENERGY STAR Idle Power Allowance (1S and 2S only)
158W
218W
370W
Measured Idle Power (watts)
104,8
137,4
199,0
Power at Full Load
*
 (watts)
184,1
247,4
310,3
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
Range of Total Estimated Energy Usage 
**
 (kWh/year)
1836 to 3225
2407 to 4334
3486 to 5436
Link to Detailed Power Calculator (if available)  
Minimum
Typical
Maximum
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
184,1W
247,4W
310,3W
Benchmark Performance Score
35.72MPixel/s
37.57MPixel/s
37.54MPixel/s
Power Performance Ratio
 (perf score/avg. power)
0,19MPixels/s/W
0,15MPixels/s/W
0,12MPixels/s/W
Link to Full Benchmark Report (Where Available)
N/A
N/A
N/A
Enabled on 
Shipment
End-User Enabling 
Required
x
x
x
x
Input Power Available & Accuracy?
Input Air Temp Available & Accuracy?
Processor Utilization Available?  
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection 
Averaging method and time period
Minimum
Typical
Maximum
Total Power Dissipation (watts)
203
240
310
Delta Temperature at Exhaust at Peak Temp. (˚C)
9
10
12
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
125m
3
/h
130m
3
/h
126m
3
/h
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
62m
3
/h
68m
3
/h
63m
3
/h
B
e
n
c
h
m
a
rk
 #
1
Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the 
highest average, sustained power possible for other workloads. 
Processor or Core Reduced Power States 
Power Saving Features
Power and Performance for Benchmark #1
SiSoftware Sandra Engineer 2009.SP4, .Net Multimedia, Double x1
ENERGY STAR® Power and Performance Data Sheet
*
 References: ASHRAE Extended Environmental Envelope Final August 1, 2008
                     Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
                     Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
Page 2 of 2
IPMI
Yes, +/- 15% above 160W and +/- 10% above 400W
Low Power Memory States
Low Power I/O States
Thermal Information
*
Linear Average calculation / 5 sec.
Processor Dynamic Voltage and Frequency Scaling
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Yes
Liquid Cooling Capability
Yes, +/- 3°C
Power and Temperature Measurement and Reporting
** 
Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100% 
full load operation.  The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0). 
Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at 
Idle, data center PUE, etc.).    
Category D: Managed Dual Installed Processor (2P) Servers
230V / 50Hz
SiSoftware Sandra Engineer 2009.SP4, .Net Multimedia, Double x1
PRIMERGY RX300 S6 E-StarFam1     (2x Quad-Core CPUs)
http://ts.fujitsu.com/products/standard_servers/e_efficient.html
Power Data