Samsung 100737108-A User Manual

Page of 83
Spinpoint M8-DVR OEM Product Manual REV 1.0 
70 
 
 
 
 
   
The  total  time  in  seconds  to complete  off-line  data  collection  activity  word  specifies  how  may  seconds  the 
device  requires  to  complete  its  sequence  of  off-line  data  collection  activity.  Valid  values  for  this  word  are 
from 0001h to FFFFh. 
Self-test execution status byte 
The self-test execution status byte reports the execution status of the self-test routine. 
 
Bits (3:0) (Percent Self-Test Remaining) 
The  value  in  these  bits  indicates  an  approximation  of the  percent  of the  self-test  routine  remaining  until 
completion in ten percent increments.  Valid values are 9 through 0. A value of 0 indicates the self-test routine 
is complete. A value of 9 means 90% of total test time remaining. 
 
Bits (7:4) (Self-test Execution Status) 
The value in these bits indicates the current Self-test Execution Status. 
 
Table 8-19 Self-test Execution Status Values 
 
 
Value
 
Description
 
The previous self-test routine completed without error or no self-test has ever been run 
The self-test routine was aborted by the host 
The self-test routine was interrupted by the host with a hardware or software reset 
A fatal error or unknown test error occurred while the device was executing its self-test 
routine and the device was unable to complete the self-test routine. 
The previous self-test completed  having a test element that failed and the test element 
that failed is not known. 
The previous self-test completed having the electrical element of the test failed. 
The previous  self-test completed  having the servo (and/or seek) test element  of the test 
failed. 
The previous self-test completed having the read element of the test failed. 
The previous  self-test  completed  having a test element  that failed and the device is 
suspected of having handling damage. 
9-14 
Reserved. 
15 
Self-test routine in progress. 
 
 
Total time to complete off-line data collection 
 
The  total  time  in  seconds  to  complete  off-line  data  collection  activity  word  specifies  how  many seconds  the 
device  requires  completing  the  sequence  of  off-line  data  collection  activity.  Valid  values  for  this  word  are 
from 0001h to FFFFh.
 
 
Off-line data collection capability
 
 
The  following  describes  the  definition  for  the off-line  data  collection  capability  bits.  If  the  value  of  all of 
these bits is equal to zero, then this device implements no off-line data collection.
 
 
    Bit 0 (EXECUTE OFF-LINE IMMEDIATE implemented bit) – If the value of this bit equals one, then the 
SMART  EXECUTE  OFF-LINE  IMMEDIATE  command  is  implemented  by  this  device.  If  the  value  of  this  bit 
equals zero, then the SMART EXECUTE OFF-LINE IMMEDIATE command is not implemented by this device. 
 
   Bit 1 (vendor specific) 
 
   Bit 2 (abort/restart off-line by host bit) – If the value of this bit equals one, then the device shall abort all 
off-line  data  collection  activity  initiated  by  an  SMART  EXECUTE  OFF-LINE  IMMEDIATE  command 
upon  receipt  of  a  new  command.     Off-line  data  collection  activity  must  be  restarted  by  a  new  SMART 
EXECUTE  OFF-LINE  IMMEDIATE  command  from  the  host.     If  the  value  of  this  bit  equals  zero,  the