Intel 31244 PCI-X User Manual

Page of 82
69
Debug Connectors and Logic Analyzer Connectivity
Debug Connectors and Logic Analyzer 
Connectivity
13
13.1
Probing PCI-X Signals
To ease the probing and debug of the PCI-X signals it is recommended to passively probe the 
PCI-X bus signals with a logic analyzer. This may be accomplished by placing six AMP
*
 
Mictor-38 connectors on the board or probing the bus with an interposer card such as the 
FuturePlus Systems
FS2007 that works with an Agilent Technologies
Logic Analyzer.
For ease of debugging the pin out of the AMP Mictor-38 connectors, the recommended pin-out 
matches the FuturePlus Systems
*
 configuration setup, which allow ease of viewing the PCI signals 
on an Agilent Technologies
Logic Analyzer. Refer to the following test equipment that is used for 
this analysis:
Two AMP 2-767004-2 surface mount connectors mounted on the target board and routed to 
the PCI-X Local bus.
Two Agilent E5346A or E5351A High-Density Adapter Cables from FuturePlus Systems or 
Agilent Technologies.
Four logic analyzer PODS.
FS1104 Software from FuturePlus.
The equivalent for other analyzers may be substituted. A FuturePlus Systems configuration file 
with the FS1104 product that matches the pinout in 
.
Table 31. 
Logic Analyzer Pod 1 (Sheet 1 of 2)
Mictor-38 #1 Pin Number Odd Pod
Logic Analyzer Channel Number
PCI-X Name
6
CLKC/16
CLK
8
15
C/BE4
10
14
C/BE5
12
13
C/BE6
14
12
C/BE7
16
11
ACK64
18
10
REQ64
20
9
UNUSED
22
8
PME
24
7
C/BEO
26
6
M66EN
28
5
C/BE1
30
4
SERR
32
3
PAR