Hitachi HDS721032CLA362 User Manual

Page of 258
Hitachi hard disk drive specifications   
134 
 
Output Parameters To The Device 
Sector Count 
Timeout  Parameter.    If  zero,  then  the  automatic  power  down  sequence  is  disabled.  If 
non-zero,  then  the  automatic  power  down  sequence  is  enabled,  and  the  timeout  interval  is 
shown below: 
 
 
Value
 
Timeout
 
 
 
----------
 
-------------------------
 
 
 
0
 
Timer disabled
 
 
 
1-240
 
Value * 5
 
 
 
241-251
 
(Value-240) * 30 minutes
 
 
 
252
 
21 minutes
 
 
 
253
 
8 hours
 
 
 
254
 
21 minutes 10 seconds
 
 
 
255
 
21 minutes 15 seconds
 
 
 
 
 
 
When  the  automatic  power  down  sequence  is  enabled,  the  drive  will  enter  Standby  mode 
automatically if the timeout interval expires with no drive access from the host. The timeout 
interval will be reinitialized if there is a drive access before the timeout interval expires.