Fujitsu IP-9610 User Manual

Page of 90
Chapter 5  Troubleshooting 
IP-9610 
48
 
 
No.  Class Status 
Description Recommended 
action 
9.   
Is the power to the communication 
destination device turned on? 
Verify the power supply and operation of 
the communication destination device. 
10.   
The LINK/ACT 
LED for the 
LAN port is not 
turned on. 
Are the LINK LEDs on this device 
and the hub turned on? 
If the LINK LEDs are not ON, the LAN 
cable is not connected.    Connect the LAN 
cable correctly. 
11.   
Is the IP address specified from the 
Web browser correct? 
Specify a correct IP address    from the Web 
browser on the control terminal. 
12.   
Are the network settings (IP 
address, subnet mask, etc.) on the 
control terminal PC correct? 
Make correct settings by referring to the PC 
user's guide and OS handbook.    If this 
device is started with the default settings 
made before shipment from the factory, see 
"Section 3.4, " Special Use of CANCEL 
Key," for the network settings for the 
control terminal PC. 
13.   
Line 
Device setting 
through a LAN 
is disabled. 
Is a reply received in response to a 
PING command issued to the IP 
address of the device? 
If a reply is not received, turn on the power 
to the device while holding down the 
Cancel key to start the system with the 
default IP address (10.0.0.1) set before 
shipment from the factory.    Confirm the IP 
address.    If the problem persists, check the 
status on the LAN.    For information on 
this startup procedure, see Section 3.4, 
"Special Use of CANCEL Key."